Cisco Systems Ethernet Module Podręcznik Użytkownika

Przeglądaj online lub pobierz Podręcznik Użytkownika dla Switche sieciowe Cisco Systems Ethernet Module. Cisco Systems Ethernet Module Messages Reference Guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - ERs erver

IBMERs erverCisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide Cisco IOS Release 12.1(14)AY

Strona 2 - Contract with IBM Corp

8 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide • SEVERITY is a single-digit code f

Strona 3 - Contents

Chapter 1. System Message Overview 9This is a sample system message:%EC-5-UNBUNDLE:Interface Gi0/2 left the port-channel Po2The messages in Chapte

Strona 4

10 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide

Strona 5 - Related Publications

© Copyright IBM Corp. 2004 11Chapter 2. Message and Recovery ProceduresThis chapter describes the switch system messages in alphabetical order by fa

Strona 6

12 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide CIGESM MessagesThis section contai

Strona 7 - Preface 5

Chapter 2. Message and Recovery Procedures 13PLATFORM_CIGESM-5-DISABLE_EXTERN: Request from Management Module: disable all external ethernet ports

Strona 8

14 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide PLATFORM_CIGESM-5-UNDR_THERMAL_THR

Strona 9 - How to Read System Messages

Chapter 2. Message and Recovery Procedures 15CMP MessagesThis section contains the Cluster Membership Protocol (CMP) messages. CMP-5-ADD: The Devic

Strona 10

16 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide DOT1X MessagesThis section contain

Strona 11

Chapter 2. Message and Recovery Procedures 17DTP MessagesThis section contains the Dynamic Trunking Protocol (DTP) messages.DTP-4-MEM_UNAVAIL: Memo

Strona 12

Note: Before using this information and the product it supports, read the general information in Appendix B.“Getting help and technical assistance”

Strona 13

18 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide DTP-5-TRUNKPORTON: Port [chars] ha

Strona 14 - CIGESM Messages

Chapter 2. Message and Recovery Procedures 19EC-5-CANNOT_BUNDLE_QOS: Removed [chars] from port channel because a QoS policy cannot be supported acr

Strona 15

20 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide EC-5-L3DONTBNDL1: [chars] suspende

Strona 16

Chapter 2. Message and Recovery Procedures 21EC-5-NOPAGP: Invalid EC mode. PAgP not enabled.Explanation This message means that PAgP is not include

Strona 17 - CMP Messages

22 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide ETHCNTR-3-LOOP_BACK_DETECTED:, Loo

Strona 18 - DOT1X Messages

Chapter 2. Message and Recovery Procedures 23PLATFORM_CAT2950-3-MEM_COPY_FAILURE: Invalid copy [dec] for table [chars].Explanation This message mea

Strona 19 - DTP Messages

24 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide PLATFORM_CAT2950-3-MEM_WRITE_FAILU

Strona 20 - EC Messages

Chapter 2. Message and Recovery Procedures 25PLATFORM_CAT2950-3-REG_READ_FAILURE: Register read failed for [chars] in [chars]Explanation This messa

Strona 21

26 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide PLATFORM_CAT2950-3-SYSTEM_INFO_FAI

Strona 22

Chapter 2. Message and Recovery Procedures 27PM-3-INTERNALERROR: Port Manager Internal Software Error [chars]: [chars]: [dec]: [chars]Explanation T

Strona 23 - ETHCNTR Messages

© Copyright IBM Corp. 2004 1ContentsPreface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 24 - HWMATM_MOD Messages

28 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide PM-4-BAD_COOKIE: [chars] was detec

Strona 25

Chapter 2. Message and Recovery Procedures 29PM-4-BAD_VLAN_ID: An invalid vlan id ([dec]) was detected.Explanation This message means that the port

Strona 26

30 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide PM-4-INT_FAILUP: [chars] failed to

Strona 27

Chapter 2. Message and Recovery Procedures 31PM-4-TOO_MANY_APP: Application '[chars]' exceeded registration limit.Explanation This messag

Strona 28 - PM Messages

32 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide SPAN-3-UNKN_ERR: An internal error

Strona 29

Chapter 2. Message and Recovery Procedures 33SPANTREE-2-CHNL_MISCFG: Detected loop due to etherchannel misconfiguration of [chars] [chars] Explanat

Strona 30

34 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide SPANTREE-2-PVSTSIM_FAIL: Superior

Strona 31

Chapter 2. Message and Recovery Procedures 35SPANTREE-2-ROOTGUARD_BLOCK: Root guard blocking port [chars] on [chars].Explanation This message means

Strona 32

36 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide This is performed by the STP subsy

Strona 33 - SPAN Messages

Chapter 2. Message and Recovery Procedures 37SPANTREE-7-BLOCK-PORT-TYPE: Blocking [chars] on [chars]. Inconsistent port type.Explanation This messa

Strona 34 - SPANTREE Messages

2 BookTitle change in special and import

Strona 35

38 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide SPANTREE_FAST MessagesThis section

Strona 36 - (PVST+) switch is

Chapter 2. Message and Recovery Procedures 39SW_VLAN MessagesThis section contains the VLAN manager messages. The VLAN manager receives information

Strona 37

40 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide SW_VLAN-4-BAD_VLAN_CONFIGURATION_F

Strona 38

Chapter 2. Message and Recovery Procedures 41SW_VLAN-4-EXT_VLAN_INTERNAL_ERROR: Extended VLAN manager received an internal error [dec] from [chars]

Strona 39

42 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide SW_VLAN-4-STARTUP_EXT_VLAN_CONFIG_

Strona 40 - STORM_CONTROL Messages

Chapter 2. Message and Recovery Procedures 43SW_VLAN-4-VTP_USER_NOTIFICATION: VTP protocol user notification: [chars].Explanation This message mean

Strona 41 - SW_VLAN Messages

44 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide UDLD-3-UDLD_INTERNAL_IF_ERROR: UDL

Strona 42

Chapter 2. Message and Recovery Procedures 45UFAST_MCAST_SW-4-MEM_NOT_AVAILABLE: No memory is available for transmitting UplinkFast packets on Vlan

Strona 43 - / file = [chars] / code =

46 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide

Strona 44

© Copyright IBM Corp. 2004 47Appendix A. Security and QoS Configuration MessagesThis appendix describes the switch error messages for configuring ne

Strona 45 - UDLD Messages

© Copyright IBM Corp. 2004 3PrefaceAudienceThis guide is for the networking professional managing the Cisco Systems Intelligent Gigabit Ethernet Swi

Strona 46 - UFAST_MCAST_SW Messages

48 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide %Error:System Defined ACEs of TCP/

Strona 47 - Vlan [dec]

Appendix A. Security and QoS Configuration Messages 49%Error:Invalid ruleThis error message means that the hardware had a problem programming the r

Strona 48

50 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide %Error:No free masks availableThis

Strona 49

Appendix A. Security and QoS Configuration Messages 51%Error:FAILURE to reinsert old ACL, errcode=XXThis error message means that a hardware failur

Strona 50

52 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide %Error:Policer Configuration Incor

Strona 51

© Copyright IBM Corp. 2004 53Appendix B. Getting help and technical assistanceIf you need help, service, or technical assistance or just want more i

Strona 52

54 BookTitle change in special and import Software service and supportThrough IBM Support Line, you can get telephone assistance, for a fee, with u

Strona 53

© Copyright IBM Corp. 2004 55Appendix C. NoticesThis information was developed for products and services offered in the U.S.A.IBM may not offer the

Strona 54

56 BookTitle change in special and import TrademarksThe following terms are trademarks of International Business Machines Corporation in the United

Strona 55 - Using the documentation

57IndexNumerics802.1X authentication messages 16see DOT1X messagesAabbreviationschar, variable field 8chars, variable field 8dec, variable field

Strona 56 - Hardware service and support

4 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide installing, configuring, or upgradi

Strona 57 - Appendix C. Notices

58 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide Ethernet controller 21hardware MAC

Strona 59

IBM@Part Number: 25K8409

Strona 60

Preface 5— How to install the management module— How to configure and use the management module• BladeCenter HS20 Installation and User’s Guide (f

Strona 61

6 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide

Strona 62 - Part Number: 25K8409

© Copyright IBM Corp. 2004 7Chapter 1. System Message OverviewThis guide describes the switch-specific system messages. During operation, the system

Komentarze do niniejszej Instrukcji

Brak uwag