QUICK START GUIDECisco ASR 1004 Router1 Documentation and Resources2 Prepare for Installation3 Rack-Mount the Router4 Connect the Router to the Networ
10Figure 5 Attaching the Cable-Management Bracket to the Cisco ASR 1004 RouterStep 3 Using the bottom rack-mount ear hole, insert the screw through ca
11Figure 6 Chassis Ground Lug Location on the Cisco ASR 1004 RouterUse the following procedure to attach the grounding lug to the chassis ground conne
12Step 5 Locate the chassis ground connector on the side of your chassis. Step 6 Insert the two screws through the holes in the grounding lug.Step 7 U
13Step 2 After you establish normal router operation, you can disconnect the terminal.Note For console and auxiliary port pinouts, see Appendix A in t
14Step 3 Insert an Ethernet RJ-45 cable into the MGMT ETHERNET port.Step 4 Insert the other end of the RJ-45 cable to your management device or networ
15Step 3 Insert the AC power cable into the power supply inlet.Step 4 Plug the power supply cable into the power source.Step 5 The power supply LEDs l
16WarningThis equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground con
17Figure 10 shows the DC power supply for the Cisco ASR 1004 Router.DC Power Supply for the Cisco ASR 1004 RouterThe Cisco ASR1004 has two of the same
18Figure 11 DC Power Supply Grounding Stud Location and Connection on the Cisco ASR 1004 RouterStep 1 Make certain that the chassis ground is connecte
19Figure 12 Cisco ASR 1004 Router DC Power Supply Terminal BlockCaution Before you continue to install the terminal block wires, stop and perform Step
21 Documentation and ResourcesDocumentation for the Cisco 1000 Series Aggregation Services Routers documentation is online with the exception of the
20Step 8 Connect the other ends of the terminal block cables to the site ground connection. Move the circuit-breaker switch to the On position (|).Thi
21–Make certain that each shared port adapter is firmly seated in its subslot and its captive screws are securely tightened.–The Cisco ASR1000-ESP10 f
22Located rp_super.ppc.nader.5g.evfc.bin Image size 211681484 inode num 12, bks cnt 51681 blk size 8*512##############################################
2332768K bytes of non-volatile configuration memory.1869396K bytes of physical memory.7798783K bytes of eUSB flash at bootflash:. --- System
24*Feb 19 17:35:22.221: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFFStep 6 Router>6 Configure the RouterUse this section for information on configuring
25Basic management setup configures only enough connectivity for management of the system, extended setup will ask you to configure each interface on
26enable password testsline vty 0 4password testno snmp-server!ip routingno bridge 1no clns routing!interface GigabitEthernet0/0/0shutdownno ip addres
27shutdownno ip addressdialer-list 1 protocol ip permitdialer-list 1 protocol ipx permit!end [0] Go to the IOS command prompt without saving this conf
28zimage at: 00807673 009B8E53initrd at: 009B9000 01006E53isord at: 01007000 0CD2A000avail ram: 00400000 00800000 Kernel load: Uncomp
29Note Basic management setup configures enough connectivity for managing the system; extended setup will ask you to configure each interface on the s
32 Prepare for InstallationThis section contains information about tools and parts, warnings, site preparation information, and information for rack-
307 After InstallationFollow the instructions in this section to replace components after installation. The following topics are covered in this sect
31Note Two power supplies must be installed in the chassis at all times to ensure sufficient cooling. The system fans are inside the power supply unit
32b. Unscrew the positive cable Kepnut screw, washer, and ground lug, and remove the stud and lead wire.c. Unscrew the earth ground Kepnut screw, wash
33Figure 13 Cisco ASR 1004 Router DC Power Supply Grounding Wire and StudStep 5 Attach the other end of the ground cable to the site ground connection
34Step 8 Tighten the Kepnut screw (use the screwdriver to tighten the ground screw in the terminal block to a torque of 8 in-lbs / 4 per.) and repeat
35Step 6 To remove the SIP, first disconnect all cables from each SPA.Step 7 Loosen the locking thumbscrews on both sides of the SIP.Step 8 Slide the
36Caution The shared port adapter must slide into the slot guides under the chassis lid. Do not allow the shared port adapter components to come in co
Americas HeadquartersCisco Systems, Inc.170 West Tasman DriveSan Jose, CA 95134-1706USAwww.cisco.comTel: 408 526-4000800 553-NETS (6387)Fax: 408 527-0
38
4Prepare for Rack-Mount InstallationBefore you begin the rack-mounting tasks:• Decide whether or not you want to front- mount or rear-mount the chassi
5Step 6 To install the Cisco ASR 1004 Router in an equipment rack, see “Four-Post Rack Installation” section on page 6 or “Two-Post Rack Installation”
6Four-Post Rack InstallationThis section describes the types of racks used for rack-mounting the chassis.Figure 3 Installing the Cisco ASR 1004 Router
7Step 5 Lift the chassis into position between the rack posts (requires two people).Step 6 Align the mounting bracket holes with the rack post holes a
8Two-Post Rack InstallationThe Cisco ASR 1004 Router can be installed in a two-post rack, either 19 inch or 23 inch.Note Inner clearance (the width be
9Step 4 Hold the chassis in position against the mounting rails and follow these steps:a. Insert the bottom screw into the third hole up from the bott
Komentarze do niniejszej Instrukcji